-40%
Carejoy Digital Electronic Colposcope Vaginal Image RCS-400/RCS-500-FDA
$ 279.83
- Description
- Size Guide
Description
Carejoy Digital Electronic Colposcope Vaginal Image RCS-400/RCS-500-3 TypesModel 1:
Description:
RCS-400 digital electronic colposcope is applicable to detect vulva, vagina, cervical disease diagnosis and inspection, especially the cell falls off, cytology positive, macroscopic invisible lesions area which is hard to confirm. With the colposcope during Biopsy it can greatly improve the rate of the positivity. It is an extremely effective method with the colposcope while examing the early cerical cancer diagnosis cytology. It consists of video collection system, microcomputer, Colposcope software. It is mainly used for processing, saving and transmitting the medical image which is capturing by the colposcope. Since the Colposcope is an integrated image processing system, which is the newly computer aided colposcope, so it is able to show the maximum performance of the colposcope and highly meets the development of digital electronical colposcope with the DSP technology requirement in the future.
Features
Lines doesn't distort or overlap.
Image quality can reach five grade of damage system or above.
Have the magnetic interference function which can avoid distortion.
Application
Vaginalitis, cervical ectropio, cervicitis, especially examining in the early diagnosis of cancer
Specifications
Video : 480,000 pixels, import high-definition digital color camera
1/4 inch color digital CCD
Minimum illumination: 0.02Lux
Lens SNR 50DB
Lens Focus distance150-350mm, amplify or narrow in the real time SP dynamic and
automatic focus system, cooperating with the manual focus adjustment
- Magnification1-126, filter technique
- Line-of-site:2.5mm-20mm-320mm
- Camera resolution: ≥480TVL
- Handle: Automatic adjustment
- Image Card: Video capture card
- Software system: WINDOWS XP operating system, static, dynamic image continual capturing and replaying, many images in one screen; easy for measuring, calculating, copying, editing freely, printing multi-format report, including the diagnosis database, offering the case analysis of reference
Function and Characteristics
-High-quality 1/4 inch color digital optical zoom lens, 27 times optical zoom, 600.000 pixels providing whole screen high-definition images
-DSP dynamic auto focus system, 8 times digital zoom cooperating with the manual focal length adjustment, super near camera, can get the clear image far from 0.1m
-AWB way internal automatically measuring light, brightness auto adjustment and electronic shock-proof function, dynamic balance of focusing around
-Quick focus CCD technique makes the clinical examination, observing, operating more conveniently
-With the high speed and professional computer, it is able to realize integrated management for freezing, capturing, saving, analysis, printing, operating the images of lesions
-High brightness light design to improve your observing effect
-Patented multi-point ring brightness LED light source and color temperature has increased 60% compared to the traditional halogen light, life can reach to 100,000 hours, reproduce more real colors of the organization, eliminate the phenomenon such as non-uniform due to color temperature and purity and blurred image magnification
-Sole Filter function to make sure to see the vein clearly with less loss of the light
-Image flare subtractive radiography, shows subcutaneous vessels form more clearly, identify extremely tiny detail more easily, special effect of observing the cervix, genital blood
-Continuous capturing static images function, and it can browse the dynamic dozens of image
-Capacity of cine loop and record continuously for different frequencies dynamic image in sampling
-Image database can be edited at any time, and dynamic review dozens of images
-Tens of image enhanced functions to improve the checking rate of micro-focus
-Capacity of internet report, and transmit the data through the internet to make an long-distance consultation and share of the information
Model 2:
Description:
RCS-400 digital electronic colposcope is applicable to detect vulva, vagina, cervical disease diagnosis and inspection, especially the cell falls off, cytology positive, macroscopic invisible lesions area which is hard to confirm. With the colposcope during Biopsy it can greatly improve the rate of the positivity. It is an extremely effective method with the colposcope while examing the early cerical cancer diagnosis cytology. It consists of video collection system, microcomputer, Colposcope software. It is mainly used for processing, saving and transmitting the medical image which is capturing by the colposcope. Since the Colposcope is an integrated image processing system, which is the newly computer aided colposcope, so it is able to show the maximum performance of the colposcope and highly meets the development of digital electronical colposcope with the DSP technology requirement in the future.
Features:
- Lines doesn't distort or overlap.
- Image quality can reach five gra
de of damage system or above.
- Have the magnetic interference function which can avoid distortion.
Application:
Vaginalitis, cervical ectropio, cervicitis, especially examining in the early diagnosis of cancer
Specifications:
-
Video matrix: SONY 800,000 pixels, import high-definition digital color camera
- 1/4 inch color digital CCD
- Minimum illumination: 0.02Lux
- Lens SNR 50DB
- Lens Focus distance150
-350mm
, amplify or narrow in the real time
- DSP dynamic and automatic focus system, cooperating with the manual focus adjustment
- Magnification1-126, filter technique
- Line-of-site:
2.5mm
-20mm
-320mm
- Camera resolution: ≥480TVL
- Handle: Automatic adjustment
- Image Card: Video capture card
- Software system: WINDOWS XP operating system, static, dynamic image continual capturing and replaying, many images in one screen; easy for measuring, calculating, copying, editing freely, printing multi-format report, including the diagnosis database, offering the case analysis of reference
Function and Characteristics:
-
High-quality 1/4 inch color digital optical zoom lens, 27 times optical zoom, 800.000 pixels providing whole screen high-definition images
- DSP dynamic auto focus system, 8 times digital zoom cooperating with the manual focal length adjustment, super near camera, can get the clear image far from
0.1m
- AWB way internal automatically measuring light, brightness auto adjustment and electronic shock-proof function, dynamic balance of focusing around
- Quick focus CCD technique makes the clinical examination, observing, operating more conveniently
- With the high speed and professional computer, it is able to realize integrated management for freezing, capturing, saving, analysis, printing, operating the images of lesions
- High brightness light design to improve your observing effect
- Patented multi-point ring brightness LED light source and color temperature has increased 60% compared to the traditional halogen light, life can reach to 100,000 hours, reproduce more real colors of the organization, eliminate the phenomenon such as non-uniform due to color temperature and purity and blurred image magnification
- Sole Filter function to make sure to see the vein clearly with less loss of the light
- Image flare subtractive radiography, shows subcutaneous vessels form more clearly, identify extremely tiny detail more easily, special effect of observing the cervix, genital blood
- Continuous capturing static images function, and it can browse the dynamic dozens of image
- Capacity of cine loop and record continuously for different frequencies dynamic image in sampling
- Image database can be edited at any time, and dynamic review dozens of images
- Tens of image enhanced functions to improve the checking rate of micro-focus
- Capacity of internet report, and transmit the data through the internet to make an long-distance consultation and share of the information
Model 3:
Description:
Description:
RCS-500: SONY Camera 830,000 pixels
Work with Laptop & Desktop
Working Principle:
RCS-500 Digital Video Colposcope is applicable to detect pathological change in Vulva, vagina and the cervix, filtering cervix cancer by fluorescence indirectly, and images management.
Application:
For clinical detection of pathological changes in vulva, vagina and cervis, filtering cervis cancer by fluorescence indirectly and images management.
Feature of Performance:
- The outlook is fashionable and convenient.
- We adopt the color digital CCD camera of high resolution and clarity. (Sony)
- The Colposcope is the sole dismountable light source, which has been got the patent.
- Bulbs adopt supper cold LED light source whose diameter is 3 mm. And in one light source there are 30 bulbs.
- There are freeze, filter, zoom in, zoom out, white balance button on the top of the camera for the speedy automatic function.
- Professional green-filter technique
- Image freeze
- White balance
- Auto focus
- Timing of acetic acid and iodine reaction tests
- Powerful image software and workstation system
Feature of Software:
- Capacity of freezing and storing static images continuously and a maximum of 99 images available for reviewing simultaneously in scroll.
- Capacity of cine loop and record continuously for different frequencies dynamic image in sampling.
- Capacity of comparison of 4 pictures in the screen, multi-orientation and dynamic consultation, copy, freeze, and other function.
- Supply hundreds of pathological reference image. Can help doctor compare the pathology and make the diagnoses.
- Need not be inputted because of abundant diagnosis information
- Capacity of internet report, and transmit the data through the internet to make an long-distance consultation and share of the information
- Color image report in multi-formats and freely input information to make the user template
- Tens of image enhanced functions to improve the checking rate of micro-focus
- Sole Filter function to make sure to see the vein clearly with less loss of the light.
- Easy operating software with icon, which can freeze and store 99 images consecutive and multi-orientation and dynamic consultation
Specification:
CCD
1/4 Super HAD CCD
Pixels
≥830,000 pixel
Illumination (min):
≤0.01Lux
Lens:
Sony 18 times focus
Resolution
≥480+ lines
Light source
30-point ringed LED, lili-white, super bright, cool, parallel, shadowless, 100, 000 hours longevity
Focus
10mm ~400mm
Zoom magnification
Optical ≥54X, Eelectronical ≥12X
Collection model
Electronic collection
Depth of field
5-200mm
Focalizing
Auto/Manual, quick
Signal-to-Noise
≥52 db
Color filter
Green
Image collection
Y
Cineloop
Y
Output port of the image
-Video/PAL/NTSC
Green Filter
Digital filter based on CCD imaging
Eliminate polarization
Y
Field of vision
Φ=2.5-320mm
Software package
Y
Operating system
Windows 2000, XP, VISTA
Standard configuration:
- Image capture system
- Image control system
- Bracket
- Two light source
- Software
- Plastic packing case
- Foldable trolley
Shipping
Return
Notes
Payment
About Us
Shipping
1. After full payment is received and cleared, we will ship it ASAP.
2. A complete and correct shipping address is essential.
3. Generally, delivery time is 15-25 business days,
if you still not received your item, please contact us, we will try our best to help you.
For
USA
buyer ,we will ship from our
USA
stock
For
other country
buyers,we will ship from
China
stock
Return
1. We accept returns, contact us within 30 days from delivery date and we will give you a full refund or exchange.
2. Only unused,undamaged and original condition item can be qualified for a return.
3. Buyer is responsible for return shipping fee.
Notes
FDA Declaration
Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
This item has been cleaned and treated according to the manufacturer's instructions.
The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods (ARTG) with the code 136606.
The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989
The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353
The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973
massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892
Seller Name: Mengjuan Nie;Country: China;City: Beijing;TEL.:86-18838974545
Payment
1. We only accept payment by Paypal.
2. Please make sure you PayPal account is valid prior bidding.
3. Great appreciation for prompt payment. Unpaid item will be failed without receiving payment in 7 days after listing ended.
About Us
In China, we are one of the professional suppliers of researching,developing, manufacturing and marketing. More than 80% of our product are exported to world markets.
If you have any questions,pls feel free to let me know.
Looking forward to our friendly & win-win cooperation.
Our working time: Monday - Friday 9:00 AM - 5:30PM (Beijing)